INSTALLATION:
MOUNTING THE DRUM MOTOR
- The Drum Motor MUST be mounted
horizontally, square to the conveyor frame and parallel to the
idler pulley. The arrow on the shaft opposite to the connection
box should be pointing upwards. (For special mounting arrangements
consult your Van der Graaf Representative)
ELECTRICAL CONNECTION
- To ensure proper electrical
connection, always consult the wiring diagram provided.
- Be sure to use qualified personnel
and observe compliance with local electrical codes.
- If in doubt, ask your Van der
Graaf Representative.
- Be sure to install the motor
with a standard fuse or circuit breaker device.
- Single phase motors must be
connected in series with a proper capacitor / condenser.
- When the motor is equipped with
a backstop device, be sure that the motor is connected for the
correct rotational direction.
PRIOR TO STARTING
- Be sure that the drum motor
is correctly wired and supplied with the proper voltage.
- Check that the pulley and conveyor
belt are unobstructed and free to rotate.
- Be careful not to over tension
the conveyor belt.
MAINTENANCE:
- Unless otherwise specified,
all Van der Graaf Drum Motors are factory filled with synthetic
lubricant.
- We recommend that oil changes
be performed every 50,000 hours of operation. No other maintenance
is required!
NOTE: Do not use oil additives, these will cause damage
to the motor insulation or seals. Also, electrically conductive
based oils, such as graphite and molybdenum disulfide, should
not be used as they will damage the motor. |